| fast track plus product matrix |
|
||||
Mask:
-
1X Chrome and Iron Oxide Master (4” to 7”), which requires the specifications outside the parameter of the Fast Track Program.
-
Chrome and Iron Oxide Reprints (4” to 6”).
-
Automatic measurements and defect inspection performed upon request.
-
PSI will add a P.C.M. (Process Control Monitors) and measure it as C.D. (Critical Dimension) when a Customer does not specify his or her C.D.
-
If a Customer requires that PSI measure specific C.D., he or she must supply a plot of these C.D. locations and/or X,Y coordinate values. PSI will manually measure up to 5 C.D. locations at no additional cost.
-
C.D. features should not be circles, curved or angular features, or larger than 20 microns; however, if a Customer requires PSI to measure them, these measurements will be based on best effort only.
- only.
Data:
- GDS, DXF, DWG, BMP, CIF, PG and other drawing formats are accepted for Fast Track Plus Products.
- Digitizing, conversion, and other various data editing services are available.
- Plots or Data can be provided for Customer’s approval.
- Data center (0,0) must match plate center.
- The area within 0.250” (6.35mm) from the edge of the plate is reserved for PSI’s P.C.M. and Serialization; therefore, the mask’s active data area (including text) should be contained within the remaining area.
- File Name (for all data formats) as well as Top Structure Name (only for GDSII) should not contain any space(s) between characters or invalid characters.
- Customer must supply data or drawing(s) and specifications necessary to build masks.
Inspection:
- Visual measurements and inspection as well as defect repair for all masks unless automatic measurements and inspection are requested.
- Automatic measurements and inspection are available at additional cost.
- Visual measurements, inspection and repair only for Chrome Reprints and Iron Oxide Masters/Reprints.
- Metrology tools are calibrated with relevant traceable standards.
- Iron Oxide features will be measured on tools calibrated with Chrome standard artifacts.
Product Specifications (Units in Microns):
Chrome |
|||
Specifications |
Master |
Reprint |
|
C.D.: |
Please contact Photo Sciences, Inc. |
2.0 minimum |
|
C.D. Tolerance (±): |
Please contact Photo Sciences, Inc. |
2X Master (0.5 min.) |
|
C.D. Uniformity (±): |
Please contact Photo Sciences, Inc. |
2X Master (0.5 min.) |
|
Registration (±) |
SL |
Please contact Photo Sciences, Inc. |
2X Master (0.5 min.) |
QZ |
Please contact Photo Sciences, Inc. |
2X Master (0.5 min.) |
|
Registration (±) |
SL |
Please contact Photo Sciences, Inc. |
2X Master (1.0 min.) |
QZ |
Please contact Photo Sciences, Inc. |
2X Master (0.5 min.) |
|
Defect: |
* 0>5.0, 0>3.0, 0>1.0, 0>0.5 |
* 0>5.0 |
|
Iron Oxide |
|||
Specifications |
Master |
Reprint |
|
C.D.: |
2.5 minimum |
3.0 minimum |
|
C.D. Tolerance (±): |
4”-6” |
≥ 0.35 |
2X Chrome Master (0.75 min.) |
7” |
Not Available |
Not Available |
|
C.D. Uniformity (±): |
4”-6” |
≥ 0.35 |
2X Chrome Master (0.75 min.) |
7” |
Not Available |
Not Available |
|
Registration (±) |
SL |
≥ 0.5 |
2X Chrome Master (0.75 min.) |
QZ |
≥ 0.35 |
2X Chrome Master (1.0 min.) |
|
Registration (±) |
SL |
≥ 0.75 |
2X Chrome Master (0.75 min.) |
QZ |
≥ 0.4 |
2X Chrome Master (1.0 min.) |
|
Defect: |
* 0>10.0 |
* 0>10.0 |
|
* Visual Inspection and Repair Only for the Defects on Iron Oxide Masks.
- Fast Track + includes any data that contain the following patterns with the dimensions listed below, which cannot be resolved under our other program, Fast Track.
Circles (Dia.) / Rings (Width) |
Squares |
Stripes |
Waveguides |
< 3.0 m |
< 3.0 m |
< 2.5 m |
Any dimensions |